Remote control bridge TCP/IP, UDP (GSM) - RS-485

Device for providing remote control and diagnostics of industrial equipment
  • Communication with the control server via GSM channel via TCP/IP, UDP or http(s) protocol
  • Communication with industrial equipment via Modbus-RTU or Modbus -TCP (RS-485) protocol
  • Provision of RS-485 - GSM data reception and transmission
  • Interface for setting addressing and RS-232 parameters
  • Operation in a wide range of input voltages from 12 to 100 VDC
  • Low Power Consumption
  • Double potential decoupling at the communication and power interface level
  • Working range from -40 to +50 C
ELMANK portfolio - Remote control bridge TCP/IP, UDP (GSM) - RS-485
Works done:
  • analysis of possible modules of GSM modules taking into account their availability in the market and necessary functionality
  • device circuitry development, including HF and digital parts
  • PCB trace
  • debugging
  • microcontroller programming
  • development of service software for windows 10 for setting data transmission parameters